SUITE 2020

BCI & NEUROTECHNOLOGY SOFTWARE

The g.tec Suite 2020 contains the software library to run data-acquisition and real-time processing experiments with g.USBamp, g.HIamp and g.Nautilus. It consists of the packages g.HIsys, g.Recorder, g.NEEDaccess and g.BSanalyze. Furthermore, it allows to control the g.Estim FES and g.Estim PRO.

From now on, software upgrades e.g. from g.Recorder BASIC to g.Recorder PROFESSIONAL are made simple.

PRODUCT HIGHLIGHTS

Rapid prototyping environment (including g.NEEDACCESS, MATLAB API, Python API, C API)
g.tec Suite 2020 can be upgraded with g.Recorder, g.BSanalyze, g.HIsys
Works with all g.tec biosignal amplifiers and stimulators
New software update feature (Notifications)
New hardware & software compatibility check
Software licenses

RAPID PROTOTYPING ENVIRONMENT TO SPEED UP YOUR RESEARCH.

Get full control over your hardware & software!

The g.tec Suite 2020 is combining all functions to create sophisticated neuroscience experiments quickly.

The rapid prototyping environment integrates seamlessly all modules from biosignal data acquisition, real-time processing, offline analysis to close-loop experiments with electrical and magnetic stimulation in one single environment.

START CONFIGURATOR

FULL HARDWARE & SOFTWARE CONTROL

It comes with the g.NEEDaccess server that provides you access to g.HIamp, g.USBamp and g.Nautilus and includes C/.NET, MATLAB and Python APIs to develop your own applications. The g.NEEDaccess server transfers the data to g.Recorder and g.HIsys.

The g.tec Suite 2020 can be upgraded with g.Recorder, g.HIsys and g.BSanalyze.

START CONFIGURATOR

g.NEEDACCESS

g.NEEDaccess is a server that facilitates simple and platform independent data acquisition from (multiple) devices over a network or direct connection, which considerably reduces workload. g.NEEDaccess allows you to acquire data easily from g.tec devices without having to take care of low-level aspects of data acquisition. The server handles acquisition and preprocessing of data such that the user receives data ready to analyze.

Since data acquisition is also realized over the network, it is now possible to collect the acquired data on a different computer than the one connected to the g.tec device (if both are connected to the network). Moreover, the server is able to provide data from a single acquisition simultaneously for multiple clients. Thus, multiple users across different systems can simultaneously review data in real-time.

PRODUCT HIGHLIGHTS

Platform independent data acquisition for g.tec devices
Data acquisition from multiple devices
Easily access ready-to-analyze data
Remote access to data acquisition devices

TECHNICAL SPECIFICATIONS

The C API is available for g.HIamp, g.Nautilus, g.USBamp

MATLAB API

The toolbox is a device driver that lets users read biosignal data like EEG, ECoG, EMG, EOG and ECG within the MATLAB environment. MATLAB is a very flexible development environment, which allows you to easily set up your own signal acquisition and analysis by utilizing all available toolboxes from MATLAB (like Statistics, Neural Networks, and Signal Processing).

One of the key advantages of the API for MATLAB is that it is fully integrated into MATLAB. Therefore, you can start data acquisitions within minutes, and build your application easily and quickly. The API for MATLAB contains commands that provide full access to the amplifier. There are commands for reading the data, setting the bandpass and Notch filters, changing the sampling frequency of the amplifier, defining bipolar derivations and calibrating the system.

PRODUCT HIGHLIGHTS

Acquire EEG, ECoG, ECG, EMG, EOG data directly within MATLAB
Control g.HIamp, g.USBamp and g.Nautilus from the MATLAB command line
Easily use the MATLAB API to handle g.tec amplifiers
Write your own MATLAB programs for on-line visualization and signal analysis
Data can be read directly into MATLAB for further offline processing
Speed up your development time – from months to hours

TECHNICAL SPECIFICATIONS

Connect Devices to the Computer: This function returns all g.tec devices available at a defined endpoint (IP address and port). Host and local IP and corresponding ports are required to use this function.
Measure Impedance: g.NEEDaccess allows the measurement of channel impedances for g.Nautilus, g.HIamp and g.USBamp.
Get Available Channels: This allows you to check which EEG channels are available.
Get Available Filters: This command reads out all available bandpass and notch filters.
Get Supported Sampling Rates: This reads out supported sampling frequencies.
Get Device Info: This command reads out the serial number of the device.
Get Scaling: This reads out the scaling factor and offset for each EEG channel.
Set Configuration: This sets the configuration of the devices.
Start Data Acquisition: This starts the data acquisition with the settings provided.
Stop Data Acquisition: This stops the data acquisition.
Get Data: This command reads out EEG data during data acquisition.

C API

The Application Programming Interface (API) allows you to access the amplifier from many programming environments. The API has functions to fully control the amplifier from C, C++, Visual Basic, LabView and many more programming languages. The API is available for Windows operating systems.

It enables you to program your own sophisticated biosignal acquisition and data processing applications. Sample programs and the well documented source code in the electronic manual serve as a template for your programs. The device driver package contains demo programs that show you the usage of all functions and help to get started with the API.

PRODUCT HIGHLIGHTS

Acquire EEG, ECoG, ECG, EMG, EOG data in your own programs
Available for Windows
Include your own sophisticated data processing algorithms
Develop stand-alone programs for biosignal analysis

TECHNICAL SPECIFICATIONS

The C API is available for g.HIamp, g.Nautilus, g.USBamp

PYTHON API

The Python API allows you to read in data from g.HIamp, g.USBamp and g.Nautilus in real-time and to perform your analysis in Python. Therefore, you can also use Python libraries to speed up the development process of your own applications.

 

ADDITIONAL SOFTWARE ADD-ONS

#

2.950 €

80% discount with g.HIamp, g.USBamp, g.Nautilus

  • Control of 16 applications
  • g.STIMbox C and MATALB API functions and demo code
  • Acquisition server for g.HIamp, g.USBamp and g.Nautilus
  • 5 programming languages supported
  • C API functions and demo code
  • .NET API functions and demo code
  • MATLAB API functions and demo batches
  • Network API functions and demo code
  • Python API and demo code
  • Data format convert to EDF/GDF
  • g.Estim FES control interface
  • g.Estim PRO control interface
  • Montage Creator
  • License Control
  • Update Handling
  • Notifications
  • System Diagnosis
  • Onboarding
START CONFIGURATOR
#

BASIC 950,00 €

5% discount with g.HIamp, g.Nautilus or g.USBamp

  • Data acquisition and high-speed visualization
  • High-speed data visualization
  • Data storage in HDF5 format
  • Review mode
  • Selection of sampling frequencies up to 38.4kHz, recording channels, bandpass and Notch filters
  • Visualization filters (bandpass, Notch)
  • Impedance check
  • Onboarding
LEARN MORE
#

PROFESSIONAL 2.950,00 €

10% discount with g.HIamp, g.Nautilus or g.USBamp

  • Data acquisition from g.HIamp, g.USBamp and g.Nautilus
  • High-speed data visualization
  • Data storage in HDF5 format
  • Review mode
  • Selection of sampling frequencies up to 38.4kHz, recording channels, bandpass and Notch filters
  • Visualization filters (bandpass, Notch)
  • Impedance check
  • Video
  • Evoked potentials
  • Heart-rate and heart-rate variability
  • Cerebral function analysis
  • Onboarding
LEARN MORE
#

BASIC 950,00 €

5% discount with g.HIamp, g.Nautilus or g.USBamp

  • Amplifier block to read data from g.USBamp, g.HIamp and g.Nautilus
  • Scope for ultra-fast raw data visualization of up to 1024 channels
  • Full control of biosignal amplifiers
  • 1 Block Library
  • 5 Simulink Models
  • Onboarding
LEARN MORE
#

PROFESSIONAL 4.950,00 €

10% discount with g.HIamp, g.Nautilus or g.USBamp

  • Amplifier block to read data from g.USBamp, g.HIamp and g.Nautilus
  • Scope for ultra-fast raw data visualization of up to 1024 channels
  • Full control of biosignal amplifiers
  • 18 Block Libraries
  • 106 Simulink Models
  • 77 Signal Processing Blocks (Feature Extraction, Pre-processing, Visualization. Classification, Paradigm)
  • P300 BCI (Visual P300, Vibro-tactile P300)
  • SSVEP BCI
  • Motor Imagery BCI (Bandpower, Common Spatial Patterns, Common Spatial Patterns with FES)
  • Physio Observer
  • g.Estim PRO and Switching Unit Interface
  • g.Estim FES Interface
  • g.STIMbox Interface
  • Transcranial magnetic stimulation
  • Eyetracking Interface
  • UDP Interface
  • Distributed EEG
  • Cortico-Cortical Evoked Potentials
  • ECoG
  • Functional Near Infrared Spectroscopy
  • Virtual and Augmented Reality
  • Neuromodulation
  • Evoked Potentials
  • Audio, Video, Keyboard, Mouse
  • Hyperscanning
  • EMG/EOG control
  • ECG and respiration
  • Hybrid BCI
LEARN MORE
#

5.950,00 €

50% discount with g.HIamp, g.USBamp or g.Nautilus

  • Biosignal off-line processing
  • Batch processing
  • 167 biosignal processing algorithms/steps included
  • Seamless integration with g.HIsys to calibrate BCI models
  • Onboarding
  • Read and analyze data from g.Recorder, g.HIsys, cortiQ
  • EEG toolbox
  • ECG toolbox
  • Classification toolbox
  • High-resolution toolbox
  • Cerebral Function Analysis
  • Spike toolbox
  • Cortico-Cortical Evoked Potentials
  • ECoG toolbox
  • TMS toolbox
  • Cascading Notch filter to suppress power line noise
  • Time-domain whitening for superb signal-to-noise ratio
LEARN MORE
#

6.900,00 €

Buy with g.HIamp, g.USBamp or g.Nautilus

  • High-gamma mapping
  • Paradigm Editor
  • Montage Creator
  • Data storage
  • Onboarding
LEARN MORE

Biosignal
Amplifiers

Wireless
EEG Systems

Invasive &
Non-Invasive Electrical Stimulators

BUILD your dream laboratory AND SAVE BIG

SET CONFIGURATOR

g.HIAMP
g.HIAMP
g.USBamp biosignal amplifier for neurophysiological research g.USBAMP
g.Nautilus Research wearable EEG headset g.NAUTILUS Multi-Purpose
g.Nautilus Flexible g.NAUTILUS PRO Flexible
g.Nautilus Research wearable EEG headset g.NAUTILUS RESEARCH
g.Nautilus PRO g.NAUTILUS PRO
STARTEN

NEED MORE INFORMATION
ABOUT THIS PRODUCT?

Send us your email so we can contact you as soon as possible.