g.USBamp - gtec's highest accuracy biosignal data acquisition and processing system

g.USBamp is a high-performance and high-accuracy biosignal amplifier and acquisition/processing system. It allows investigation of brain-, heart- and muscle-activity, eye movements, respiration, galvanic skin response and many other physiological and physical parameters. Due to its technical specifications and various software options, this instrument became a standard for many different fields of research, including neuropsychology, life science, medical research and biofeedback/neurofeedback/BCI research.

g.USBamp is USB 2.0 enabled  and comes with 16 simultaneously sampled biosignal  channels with 24 bits. A total of 4 independent grounds  guarantee no interference between the recorded signals.

Award winning technology

The amplifier connects easily to the USB socket on your PC/notebook and can immediately be used for data recording.

Build a multi-channel system with more than 16 channels using multiple g.USBamp devices. A synchronization cable guarantees that all devices are sampling with exactly the same frequency.

The amplifier has an input range of ± 250 mV, which allows recording of DC signals without saturation.
 Digital inputs and outputs allow the recording of trigger channels together with the biosignal channels to easily pass analysis results to the outside world.
 A short-cut input allows connecting the amplifier inputs quickly to ground potential to protect the amplifier against overflows, which may occur in operating rooms with gamma knifes or other environments.

Product Highlights

  • 16 DC-coupled wide-range input channels per unit, 4 independent grounds, record any type of signal (EEG/ECoG/ECG/EMG/EOG/spikes/...), connect various sensors, stack units for 32/48/64/... channels.
  • 24-bit resolution with simultaneous sampling of all channels with up to 38.4 kHz, digital signal filtering and preprocessing, connect via USB 2.0.
  • works with passive and with active electrodes, 8 digital trigger inputs/unit, 4 digital outputs/unit, new simplified synchronization of units.
  • internal digital bandpass and notch filters, built-in calibration unit and impedance checking.
  • easy configuration and setup via the software, high-speed online data processing for SIMULINK and for LabVIEW available, recommended by BCI2000 & approved under OpenViBE
  • driver package/API available
  • CE-certified and FDA-approved medical device, safety class: II, conformity class: IIa, type of applied part: CF

More Product Details

Input channel properties

g.USBamp uses wide-range DC-coupled amplifier technology in combination with 24-bit sampling. The result is an input voltage range of +/- 250 mV with a resolution of < 30 nV! This means that any electrophysiological signal can be recorded directly without additional hardware. Neither high electrode offset voltage nor big artifacts resulting from electrical or magnetic stimulation will saturate the amplifier inputs. This feature is an important requisite for various artifact treatment and correction techniques. The use of digital filters avoids hardware-related variations between channels. g.tec's active electrode system can also be connected directly, as well as all of our sensors (e.g. GSR, skin temperature, blood pressure, oxygen saturation, respiration effort and airflow, pulse plethysmography, acceleration, limb movements, snoring sounds, and many more).

Accuracy and data quality

Each of the 16 analog to digital converters is operating at 2.4576 MHz. An oversampling of 64 times yields the internal sampling rate of 38.400 Hz (per channel and for all channels!). In addition, a powerful floating point Digital Signal Processor performs oversampling and real-time filtering of the biosignal data (between 0 Hz - 2.400 Hz).
Therefore, a typical sampling frequency of 256 Hz yields an oversampling rate of 9.600. This results in a very high signal to noise ratio, which is especially critical when recording evoked potentials in the EEG or identifying small amplitude changes in high-resolution ECG recordings. You are measuring far below the noise-range of conventional amplifiers.

Add more channels or split systems

To set up a multi-channel system (32/48/64/... channels), g.USBamps can be stacked. Just add another 16 channels by connecting one more unit to the system. To assure 100% simultaneous sampling of all channels, a simple "SYNC cable" is used to interconnect the devices (via a plug in the rear side). Each input channel can be used for any type of signal (electrophysiological signals or external physiological or physical sensors).

On the other hand, if you have a 64 channel system consisting of 4 amplifiers, you can split the system to have 4 units available.

Test signal generation and calibration

The amplifier can generate an internal sinusoidal-, rectangular-, sawtooth or white-noise test signal. The amplitude and frequency of the signal can be modified to test the recording and analysis chain. An internal calibration unit periodically detects offset and gain values for each channel and uses these values for automatic internal correction. This technique provides topmost accuracy - especially needed for high resolution EEG and source derivation/localization.

Skin-electrode impedance

In order to obtain top-quality EEG recordings, the transition impedance between the skin and the electrode must be checked. The internal impedance testing unit measures the impedance for the individual electrodes and the results are displayed in the software. Bad electrodes can be identified easily and skin treatment and gel application can be performed during the impedance testing.

Software options

g.tec's philosophy is to provide a broad spectrum of software solutions for different groups of users (e.g. for engineers, researchers & scientists, physiologists, and medical staff, but also for software developers & programmers). From comfortable Windows-based recording software to MATLAB/SIMULINK and LabVIEW Highspeed Online-Processing environment and device drivers as well as APIs, you will find the appropriate tools for your application. Please see the list of related products/software below for more details. g.USBamp is also supported by some open source research communities such as OpenVibe and BCI2000.

Important information

As with all g.tec biosignal amplifiers, we give a full 5-years warranty on g.USBamp.
g.USBamp is a safe certified medical device (CE and FDA) for research in humans, even for invasive recordings such as electrocorticography (ECoG). It must not be used for patient monitoring or determination of brain death. Medical diagnoses and decisions about treatment of diseases must not be based (solely) on results obtained with this device.

For ECoG

Ad-Tech grid electrode for ECoG for connecting with the g.USBamp


Available configurations

Complete Solutions

read more g.BCIsys: Specs & Features — Complete MATLAB-based Brain-Computer Interface development/research system
product no.: 6037 read more g.USBamp CARDIObundle, PC included — system for ECG and blood pressure recordings
product no.: 6032 read more RehaBCI, PC included — 32 channels; consisting of: g.BCIsys32USB; g.VRsys; g.GAMMAbundle for g.USBamp CSP; g.UDPinterface; g.USBamp common spatial patterns model
read more g.EEGsys: Specs & Features — complete EEG research systems, ready-to-go installation
read more g.FEATUREmonitor: Specs & Features — Cerebral and autonomous function monitor & video-EEG
read more intendiX: Specs & Features — Patient-ready EEG-based spelling system
read more g.BCI2000sys: Specs & Features — Complete BCI system for g.USBamp and g.MOBIlab+ with BCI2000

Hardware and Accessories

product no.: 0230 read more g.USBamp 8 channels — g.USBamp with 8 channels; 256Hz; no DIG I/O
product no.: 0216 read more g.USBamp 16 channels — g.USBamp with 16 channels; 38.4 kHz per channel; 4 separated grounds

See some related products

Electrodes and Sensors

read more g.GAMMAsys: Specs & Features — active electrode system for EEG/EMG/EOG/ECG
read more g.EEGcap: Specs & Features — EEG cap & electrode system
read more g.SAHARA: Specs & Features — active dry EEG electrode system
read more g.Electrodes: Specs & Features — various active and passive electrodes for electrophysiological recordings
read more g.Sensors: Specs & Features — various sensors for physiological and physical signals

Hardware and Accessories

read more g.HEADstage: Specs & Features — miniaturized pre-amplifier
product no.: 0247 read more g.Power - for g.USBamp — medical mains power supply for g.USBamp; 110/230 V; 50/60 Hz power line; single 5 V supply
product no.: 0247b read more g.Power - for 2 g.USBamps — medical mains power supply for g.USBamp; 110/230 V; 50/60 Hz power line; 2 x 5 V supply
product no.: 0247a read more g.Power - for 4 g.USBamps — medical mains power supply for g.USBamp; 110/220 V; 50/60 Hz power line; 4 x 5 V supply
product no.: 0251a read more g.ACCUpack for g.USBamp — rechargeable battery pack; 12V and 5V, 4.5 Ah; for g.USBamp & adapter cable (253a)
product no.: 0252 read more Charging device for g.ACCUpack — automatic charging device for battery pack g.ACCUpack (0151a/c), 110/120 V; 50/60 Hz power line;regional adapter for EU, USA, UK,CN/AUS
product no.: 0281 read more g.USBamp synch cable — synchronisation cable for 2 g.USBamps; for serial numbers UA->UA or UB->UB
product no.: 0283 read more g.USBamp synch cable (4 x) — synchronization cable for 4 g.USBamps
product no.: 0279 read more g.INTERsync — g.USBamp interversion synchonization box between UA and UB, master is UB
product no.: 0225 read more g.USBamp cable for short-cut function (SC) — 3m cable with 3pin screw terminal
product no.: 0274 read more g.TRIGbox: Specs & Features — multimode trigger conditioner box
product no.: 0277 read more Trigger cable for g.USBamp UB — DIO break-out of cable to DSUB15 female; for UB-xxx.xx.xx
product no.: 0278 read more Adapter cable for trigger cable — DSUB15-male to 6x BNC male adapter (including 6x CINCH adapter)
product no.: 0275 read more Trigger cable for g.USBamp UB, open leads — trigger cable with open leads, for DIG I/O Trigger for UB-xxx.xx.xx
product no.: 3012 read more medical isolation transformer — 600 VA, REO-MED, 6 outputs
product no.: 5051 read more g.USBamp water-proof heavy duty case — 100 % water-proof heavy duty case for g.USBamp equipment
product no.: 0219a read more ElectroCap-adapter cable to DSUB25 male for g.USBamp — adapter cable for 25 pin SUB-D 16 channels Electrocap for g.USBamp; standard: A: Screening
product no.: 10040 read more Medical device inspection — recurring medical device inspection (EN62353: 2008) for g.USBamp and g.BSamp
read more g.PAH: Specs & Features — programmable attenuator and headphone buffer
product no.: 1302 read more g.STIMbox: Specs & Features — stimulation box to record and generate trigger signals; 16 digital outputs and 14 digital inputs; C API, MATLAB API and Simulink driver
product no.: 0255 read more Connection cable XLTEK 32 channel to 2 g.USBamps — Connection cable male D-SUB 37pin to 2 g.USBamps; separate GND and REF cables included, connection length 1.75 m; special wiring to be confirmed at order
product no.: 0256 read more Connection box Stellate eAmp 64 channel to 4 g.USBamps — Connection box VHDCI connector to 4 g.USBamps; separate GND and REF cables included, connection length 1.75 m; special wiring to be confirmed at order
product no.: 0257 read more Special 64 channel break out and connection box Nihon Kohden Neurofax 64 channel to 4 g.USBamps — g.tec-65pin connector to 4 g.USBamps; separate GND and REF cables included, connection length 1.75 m; special wiring to be confirmed at order
product no.: 0258 read more Connection cable from 64 channel breakout box to Nihon Kohden Neurofax A connector — Nihon-Kohden-80pin connector to g.tec-65pin connector; connection length 10m
product no.: 0259 read more Connection cable from 64 channel breakout box to Nihon Kohden Neurofax B or C connector — Nihon-Kohden-68pin connector to g.tec-65pin connector; connection length 10m

Related Media and Documents

g.USBamp

log in required
application/pdf
Connecting Parallel Port to gUSBamp — 14/09/2011 — 178.95 kB
log in required
application/pdf
gUSBamp30Basics — 24/10/2011 — 2.80 MB
log in required
application/pdf
gUSBamp30Gebrauchsanweisung_v2_11_03_de — 14/09/2011 — 906.22 kB
log in required
application/pdf
gUSBamp30_InstructionsForUse — 14/09/2011 — 779.23 kB