FLEXIBLE EEG DESIGNED FOR CLINICAL EEG WORKFLOWS

Designed for modern clinical workflows with fast patient preparation, interchangeable dry, wet, and hybrid electrode strands, simplified infection control, and reliable wireless EEG acquisition for hospitals, rehabilitation, and clinical neuroscience.

NAUTILUS PRO FLEXIBLE

MODULAR WIRELESS EEG PLATFORM, MULTIPLE CLINICAL WORKFLOWS

START CONFIGURATOR

patented, fda cleared, ce certified

WEARABLE EEG SYSTEM DESIGNED FOR CLINICAL WORKFLOWS

Clinical EEG requires more than high-quality brain signal acquisition. Healthcare professionals need fast patient preparation, reliable recordings, flexible electrode configurations, and efficient cleaning between consecutive examinations. The g.Nautilus PRO Flexible was developed specifically for these clinical workflows, combining research-grade EEG performance with a modular design that simplifies everyday use in hospitals, rehabilitation centers, and clinical research environments.

The wearable EEG system supports 8, 16, 19, or 32 channels and allows users to exchange complete electrode strands within seconds while using the same amplifier. Depending on the application, clinicians can choose g.SAHARA hybrid dry electrodes, g.SCARABEO wet electrodes, or Safety Connector strands for additional biosignal sensors. This flexibility enables one amplifier to support different electrode types, cap sizes, patient populations, and recording protocols without changing the acquisition hardware.

Unlike conventional EEG systems, the removable electrode strands can be cleaned, disinfected, and exchanged independently of the amplifier. This significantly simplifies hygiene management, reduces turnaround time between patients, and supports efficient workflows in clinical environments where multiple recordings are performed every day.

Whether used for clinical EEG, neurorehabilitation, disorders of consciousness, epilepsy research, EEG-TMS, EEG-fNIRS, or mobile neuroscience, g.Nautilus PRO Flexible provides a flexible, reusable, and future-proof platform that adapts to changing clinical and research requirements.

PRODUCT HIGHLIGHTS

Modular clinical EEG platform with interchangeable electrode strands for flexible clinical workflows
One reusable amplifier compatible with g.SAHARA hybrid, g.SCARABEO wet, and Safety Connector strands
Strand with g.SAHARA hybrid EEG electrodes for dry and gel recordings
Strand with g.SCARABEO EEG electrodes for wet recordings
Strand with Safety Connectors to connect g.Sensors or other biosignal sensors
Fast cleaning and simplified infection control through removable electrode strands; fits ideally for medical applications
Available with 8/16/19/32 channels and an integrated 3-axis accelerometer
24-bit wireless EEG acquisition at 500 Hz with real DC-coupled amplifiers
Wireless 2.4 GHz digital transmission with a range of up to 10 meters indoors
Internal impedance check for g.SCARABEO electrodes
Supports EEG-TMS, EEG-tDCS, EEG-fNIRS, neurorehabilitation, bedside assessment, and multimodal neuroscience research
Complete g.tec software ecosystem including g.Recorder, g.HIsys, g.BSanalyze, g.NEEDaccess, and support for Python, MATLAB, Simulink, and Lab Streaming Layer (LSL)
CE certified and FDA cleared medical EEG headset

TECHNICAL SPECIFICATIONS

Weight< 143 g without electrode grid
Size77 (L) x 100,5 (W) x 31,75 (H) mm
ColorBLACK
Sensitivity±2.25 V, ±1.125 V, ±750 mV, ±562,5 mV, ±375 mV, ±187.5 mV (software selectable)
InterfaceWireless 2.4 GHz ISM band
Digital inputs8 digital trigger inputs at Base Station
SupplyBuilt-in lithium ion battery
Battery runtime>10 hours with 32 channels
Amplifier type Real DC coupled
32 × ADC 24 Bit (1.024 MHz internal sampling per channel)
Noise level< 0.6 µV RMS between 1 and 30 Hz (at highest input sensitivity)
Input channels32 mono-polar / 16 bi-polar channels with GND and REF (software selectable)
ChargingQi inductive wireless charging
Impedance measurementIntegrated impedance check for g.SCARABEO electrodes
Input impedanceDC > 1 GOhm
Applied partBF
Safety classII
Certification and StandardsCE certified and FDA cleared medical device
StandardsIEC60601-1 3rd, IEC60601-1-2, IEC62304, IEC60601-2-26, ISO 14971 10993-1, 62366, 2010-2012 IEEE Recommended Practice for Neurofeedback Systems

“We have several ongoing studies. One of these studies is to extend human arm control to new approaches that control more than two arms with the help of brain-computer interfaces.”

Hiroshi Ishiguro, PhD - Intelligent Robotics Laboratory, Japan

“g.Nautilus wireless EEG amplifiers allow us to investigate freezing of gait in Parkinson’s disease, a dangerous symptom for the aging population as it can lead to falls. We can synchronize the EEG signals with VICON motion capture data seamlessly, without adding extra burden on our patients such as backpacks, or wired in hardware following them.”

Aysegul Gunduz, PhD - University of Florida, USA

MULTIMODAL PHYSIOLOGICAL MONITORING

The g.Nautilus PRO Flexible can simultaneously record EEG and additional physiological signals using the Safety Connector strand. Connect EMG, ECG, EOG, GSR, respiration, temperature, pulse, blood pressure, and other biosignals to create synchronized multimodal recordings for clinical assessments, neurorehabilitation, Brain-Computer Interface applications, and neuroscience research. The modular design allows researchers to configure the recording setup for each study without changing the amplifier, providing one flexible platform for multimodal neuroscience and clinical research.

BODY SENSORS

NEUROREHABILITATION

Neurorehabilitation requires reliable EEG recordings while patients perform natural movements during therapies such as upper-limb rehabilitation, gait training, motor imagery, and Brain-Computer Interface training. The lightweight wireless g.Nautilus PRO Flexible minimizes cable-related artifacts, allowing patients to move more naturally during recording sessions.

g.GAMMAcaps with pre-mounted electrode strands enable fast patient preparation and consistent electrode placement, while the removable strands simplify cleaning between therapy sessions. Combined with the g.tec software ecosystem, g.Nautilus PRO Flexible supports stroke rehabilitation, motor recovery research, and real-time neurorehabilitation applications.

BRAIN ASSESSMENT FOR DISORDERS OF CONSCIOUSNESS, ALS & MORE

Patients with disorders of consciousness (DOC), amyotrophic lateral sclerosis (ALS), ADHD, and other neurological conditions often present significant challenges for EEG acquisition due to involuntary movements, limited attention spans, fatigue, or restricted recording time.

The g.Nautilus PRO Flexible was developed for demanding clinical workflows where fast preparation and reliable EEG acquisition are essential. g.GAMMAcaps with pre-mounted electrode strands connect within seconds for rapid patient setup and consistent electrode placement. The lightweight wireless design improves patient comfort, reduces cable-related artifacts, and enables reliable bedside brain assessments and neurorehabilitation with the complete g.tec clinical software ecosystem.

SIMULTANEOUS EEG, TMS AND TDCS

Simultaneous electroencephalography (EEG) with transcranial magnetic stimulation (TMS) and transcranial direct current stimulation (tDCS) enables researchers to investigate cortical excitability, functional connectivity, neuroplasticity, and the immediate effects of non-invasive brain stimulation with millisecond temporal resolution.

The g.Nautilus PRO Flexible supports wireless EEG acquisition during TMS and tDCS experiments. Combined with g.BSanalyze, dedicated post-processing algorithms automatically remove TMS and tDCS stimulation artifacts within milliseconds, enabling reliable analysis of brain activity after stimulation. This makes the platform well suited for neuromodulation research, cognitive neuroscience, neurorehabilitation, and closed-loop Brain-Computer Interface applications.

EXCEPTIONAL PERFORMANCE EEG SYSTEM

Wearable EEG headsets are becoming increasingly important in medical and clinical environments because more and more studies are conducted in the field. For these reasons, g.tec developed different versions of g.Nautilus wearable EEG headsets. Their designs are tiny, lightweight, wireless and set a new standard of usability.

In combination with g.SAHARA hybrid or g.SCARABEO and g.LADYbird wet EEG electrode technology, researchers get top-quality recordings without the burden of data loss. Make the most of your precious recording time with g.Nautilus!

SHOP NOW

NEUROMARKETING AND AUDIENCE RESEARCH

Understanding audience engagement requires more than questionnaires and subjective feedback. Electroencephalography (EEG) enables researchers to measure neural responses with millisecond temporal resolution, providing objective insights into attention, emotional engagement, cognitive workload, and user experience while participants interact with videos, music, games, or other multimedia content.

Dolby Laboratories uses g.Nautilus PRO Flexible to investigate how audiences respond to audiovisual experiences. By combining wireless EEG with additional physiological measurements such as heart rate and skin conductance, researchers can better understand emotional responses, identify highly engaging content, and optimize immersive entertainment experiences.

COMPLETE CLINICAL EEG ECOSYSTEM

Modern clinical EEG requires more than high-quality brain signal acquisition. Researchers and clinicians need integrated software for acquisition, real-time processing, offline analysis, custom application development, and interoperability with established scientific tools. The g.Nautilus PRO Flexible is part of the complete g.tec clinical ecosystem, enabling users to move seamlessly from data acquisition to multimodal analysis, Brain-Computer Interface development, and clinical research while maintaining compatibility with open scientific workflows.

CLINICAL APPLICATIONS

Clinical ApplicationsWhy g.Nautilus PRO Flexible
Stroke rehabilitationWireless movement recordings
Disorders of ConsciousnessFast preparation
ALSComfortable long recordings
ADHDNatural behaviour
EEG-TMSCompatible with stimulation
EEG-fNIRSMultimodal
NeurofeedbackReal-time feedback
Cognitive neuroscienceMobile EEG
Human factorsWireless recordings
Clinical researchCE-certified and FDA-cleared

COMPLETE SOFTWARE ECOSYSTEM

SoftwarePurpose
g.RecorderEEG acquisition
g.HIsysReal-time processing
g.BSanalyzeOffline analysis
g.PypePython SDK
g.tec Suite 2024APIs
MATLAB
Simulink
Python
LSL

FREQUENTLY ASKED QUESTIONS

Why is a modular EEG system beneficial for clinical workflows?

The modular design of g.Nautilus PRO Flexible separates the reusable wireless amplifier from the interchangeable electrode strands. Each strand contains 8, 16, 19, or 32 EEG electrodes and can be configured with g.SAHARA hybrid dry electrodes, g.SCARABEO wet electrodes, or Safety Connectors for additional physiological sensors. Depending on the clinical application, clinicians simply disconnect one strand and attach another without replacing the amplifier.

This allows one EEG system to support different electrode technologies, patient populations, cap sizes, and multimodal recording setups while reducing preparation time, simplifying cleaning and disinfection, and improving workflow efficiency in hospitals and clinical research.

Can I switch between dry, wet, and hybrid EEG electrodes?

Yes. g.Nautilus PRO Flexible supports interchangeable g.SAHARA hybrid, g.SCARABEO wet, and Safety Connector strands. The same reusable amplifier can be combined with different electrode technologies depending on the application. The Product Configurator allows users to customize the system by selecting the appropriate electrode strand, channel configuration, and accessories for dry EEG, wet EEG, or multimodal physiological recordings.

Can I use one amplifier with multiple EEG caps?

Yes. One g.Nautilus PRO Flexible amplifier can be combined with multiple g.GAMMAcaps and interchangeable electrode strands, making it easy to adapt to different head sizes, patient populations, and recording protocols.

Is g.Nautilus PRO Flexible suitable for hospitals and clinical research?

Yes. The system is CE-certified and FDA-cleared for medical applications and was specifically designed for hospitals, rehabilitation centers, and clinical neuroscience research where fast preparation, reliable recordings, and efficient cleaning are essential.

Can I record EEG during patient movement?

Yes. The wireless design minimizes cable-related artifacts and allows patients to move during neurorehabilitation, gait analysis, motor imagery, cognitive neuroscience, and other movement-based experiments.

Can I perform simultaneous EEG-TMS or EEG-tDCS experiments?

Yes. g.Nautilus PRO Flexible supports simultaneous EEG recordings during TMS and tDCS. Combined with g.BSanalyze, dedicated artifact removal algorithms enable reliable analysis of brain activity following stimulation.

Can I combine EEG with fNIRS and other neuroimaging technologies?

Yes. g.Nautilus PRO Flexible integrates with g.SENSOR fNIRS and other multimodal research technologies, enabling synchronized recordings for neurovascular coupling, cognitive neuroscience, Brain-Computer Interfaces, and clinical research.

Can I record additional physiological signals together with EEG?

Yes. Using the Safety Connector strand, g.Nautilus PRO Flexible can simultaneously record EMG, ECG, EOG, GSR, respiration, temperature, pulse, blood pressure, and other physiological signals for multimodal neuroscience and clinical studies.

Which clinical applications is g.Nautilus PRO Flexible designed for?

The platform is widely used for neurorehabilitation, disorders of consciousness, ALS, epilepsy research, ADHD research, Brain-Computer Interfaces, EEG-TMS, EEG-fNIRS, cognitive neuroscience, human factors, and clinical brain monitoring.

Can I develop custom EEG applications with g.Nautilus PRO Flexible?

Yes. The platform integrates with the g.tec software ecosystem, including g.Pype, g.HIsys, g.tec Suite 2024, g.Recorder, and g.BSanalyze, allowing researchers to develop custom acquisition, processing, machine learning, and Brain-Computer Interface applications.

Why is g.Nautilus PRO Flexible well suited for neurorehabilitation?

The wireless design allows patients to move during therapy while reducing cable-related artifacts. Combined with rapid patient preparation and interchangeable electrode strands, the platform supports efficient EEG recordings for motor recovery, gait training, Brain-Computer Interface therapy, and rehabilitation research.

Why choose g.Nautilus PRO Flexible over a conventional clinical EEG system?

Unlike conventional EEG systems, g.Nautilus PRO Flexible features a modular architecture with interchangeable electrode strands that support dry, wet, and multimodal recordings using the same reusable amplifier. This reduces preparation time, simplifies cleaning, adapts to different clinical workflows, and provides a flexible platform for hospitals, rehabilitation centers, and clinical neuroscience research.

GET YOURS