SENSORS | g.tec medical engineering GmbH

SENSORS

BIOSIGNAL SENSORS

SHOP NOW

EEG, EOG and EMG can be measured with electrodes attached to the human body. The electrodes pick up the electrical activity of the underlying neurons. Different sensors are required to measure other signals from the body. Therefore, g.tec provides various sensors for physiological and physical signals.

All sensors provide analog output signals, and are designed to be connected directly to the amplifier inputs or to the analog inputs of the data acquisition system. For safety reasons, all sensors, adapter cables and interface boxes are equipped with DIN 1.5-mm touchproof safety connectors.

BODY SENSORS

Ultra high-density EMG sensor
fNIRS sensor
Temperature Sensor
Blood pressure monitoring sensor
Snoring sensor
Respiration effort sensor
Respiration airflow sensor
Oxygen saturation sensor
Galvanic skin response sensor
Acceleration sensor
Limb movement sensor

TECHNICAL SPECIFICATIONS

Input connectorsDIN 1.5 mm touchproof safety connectors
Safety classII

8 FNIRS SENSOR

g.SENSOR 8 fNIRS allows you to record functional near-infrared spectroscopy. With g.tec’s biosignal amplifiers, you can pick up EEG signals at the same time.

LEARN MORE

TEMPERATURE SENSOR

The temperature sensor can be used to measure skin temperature between 20° C – 45° C (accuracy 0.2° C). The sensor is already calibrated and provides an output voltage of 0…200 mV.

SHOP NOW

BLOOD PRESSURE MONITORING SENSOR

The blood pressure monitoring sensor allows non-invasive BP recording and can be used as a stand-alone system as well. The analog output signal (continuous BP in mmHg) can be recorded with other parameters and biosignals with g.tec systems.

SHOP NOW

SNORING SENSOR

Piezo-electric snoring sensor picks up tracheal sounds for sleep research. The sensor can be placed on the neck of the patient.

SHOP NOW

RESPIRATION EFFORT SENSOR

Piezo-electric crystal sensor in a robust belt system. Can be used to record chest and abdominal respiration waveforms independently. Our respiration sensors connect directly to amplifier inputs.

SHOP NOW

RESPIRATION AIRFLOW SENSOR

This thermistor sensor is placed in front of nose and mouth and measures temperature changes in inhaled and exhaled air. The resulting respiration signal is very robust against movement artifacts.

SHOP NOW

OXYGEN SATURATION SENSOR

Two light sources with different wave lengths are used to measure the saturation of oxygen in the blood (SpO2) and the pulse. A sensor for the index finger or ear-lobe is available. A calibrated output signal is provided.

SHOP NOW

GALVANIC SKIN RESPONSE

This method is also called EDA (electro-dermal activity) or skin conductance, where two small electrodes are placed on fingers without gel. The isolated circuit guarantees no interference with other electrodes on the body. Technical details: 0 – 30 µS, 1µS (micro MHO) calibration button.

SHOP NOW

ACCELERATION SENSOR

The acceleration sensor can be applied on the subject’s body or directly in a simulator, vehicle or airplane to monitor g-forces, acceleration and vibration. Technical details: 3-axes, +/- 3 g acceleration.

SHOP NOW

LIMB MOVEMENT SENSOR

The piezo-electric sensor is placed on the ankle to detect movements of the feet during sleep to investigate restless leg syndrome (RLS) and periodic limb movements (PLMs).

SHOP NOW

NEED MORE INFORMATION
ABOUT THIS PRODUCT?