Menu
    • Home
    • About
    • INSIGHTS
    • Products
          • Biosignal Amplifiers

            • g.HIAMP
            • g.USBAMP RESEARCH
            • g.HIAMP NIRX
            • g.HIAMP TOBII PRO FUSION
          • Wearable EEG Headsets

            • g.NAUTILUS PRO FLEXIBLE
            • g.NAUTILUS MULTI-PURPOSE
            • g.NAUTILUS RESEARCH
            • g.NAUTILUS FNIRS
            • g.NAUTILUS NIRX
            • g.NAUTILUS TOBII PRO GLASSES 3
          • Electrode Systems

            • g.PANGOLIN HIGH-DENSITY EEG
            • g.SCARABEO EEG ELECTRODES
            • g.SAHARA HYBRID EEG ELECTRODES
            • g.LADYBIRD EEG ELECTRODES
            • g.LADYBIRD ACTIVE TMS-EEG
            • g.LADYBIRD PASSIVE TMS-EEG
          • EEG CAPS

            • g.GAMMACAP
          • Sensors

            • BODY SENSORS
          • Electrical Stimulators

            • g.ESTIM FES
            • g.ESTIM PRO
            • SWITCHING UNIT
          • External Trigger Generation

            • g.STIMBOX
            • g.TRIGBOX
            • g.AUDIOBOX
          • Software Platform

            • G.TEC SUITE 2024
            • g.HISYS
            • g.RECORDER
            • g.BSANALYZE
            • g.PYPE SDK FOR PYTHON
          • Unicorn Hybrid Black

            • UNICORN HYBRID BLACK
            • UNICORN NAKED BCI DEV BOARD
            • UNICORN EDUCATION KIT
            • UNICORN SUITE SOFTWARE
            • RESOURCES
          • Unicorn BCI Core-8

            • UNICORN BCI CORE-8
            • RESOURCES
          • Unicorn BCI Core-4

            • UNICORN BCI CORE-4 HEADBAND
            • RESOURCES
          • Unicorn tDCS Core-2

            • UNICORN TDCS CORE-2
            • RESOURCES
          • Complete Solutions

            • RECOVERIX NEUROTECHNOLOGY
            • CORTIQ RAPID CORTICAL MAPPING
            • MINDBEAGLE BRAIN ASSESSMENT
          • Workshops & Events

            • WORLD TOUR 2026/2027
            • SFN 2026 WORKSHOP
            • THE SPRING SCHOOL 2027
          • RESOURCES

            • PLAN YOUR BCI LAB
            • BCI FOR AI
            • BCI PLATFORM
            • BCI AWARD 2026
            • RECOMMENDED CITATION LIST
    • Find g.tec in your country
    • Contact
    • Shop
  • News
  • Animal EEG Through Fur: Validation, Setup and Behavior Sync with the Unicorn BCI Core-8

Animal EEG Through Fur: Validation, Setup and Behavior Sync with the Unicorn BCI Core-8

Short answer: Yes, animal EEG can be recorded through fur in awake, freely moving animals. With the 8-channel Unicorn BCI Core-8, gold cup electrodes and adhesive paste, a peer-reviewed study recorded auditory evoked potentials in two unsedated, unrestrained dogs, with a clear N100 response. Field recordings with the same system include horses, a pig, a cow, a goat and an alpaca. This guide explains the setup, how to check signal quality, and how to synchronize EEG with animal behavior.

Animal EEG has a practical problem that human EEG does not: fur, movement and animals that will not sit still under a cap. Traditional veterinary EEG often relies on sedation or restraint, which changes the very brain states researchers want to study. A miniature wireless system removes both constraints. For animal EEG, the open questions are the ones buyers ask first: Does it really work through fur? How good is the signal? And how do I link the EEG to what the animal is doing?

Animal EEG through fur: Unicorn BCI Core-8 recording EEG on a dog

The Evidence: Auditory Evoked Potentials in Free-Moving Dogs

The strongest evidence for EEG through fur with the Unicorn BCI Core-8 comes from a study presented at IEEE SMC 2025: Canine EEG in Natural Settings: Auditory Evoked Potentials During Free Movement Using a Miniature Wireless System (Schreiner L, Sieghartsleitner S, Fummo M, Guger C, 2025).

Study parameter Value
Animals 2 dogs of different breeds, awake, unrestrained, no sedation
System Compact wireless 8-channel EEG system
Electrodes 8 gold cup electrodes, positioned symmetrically on the scalp
Sampling rate 250 Hz
Paradigm Auditory oddball (target and non-target tones)
Signal quality check Power spectral density analysis
Main result Auditory evoked potentials reliably separated target from non-target tones, with a clear N100 response
Topography Largest amplitudes over the right lateral temporal region in both dogs

The authors conclude that rapid, stress-free EEG acquisition is feasible in dogs and other non-human animals, and that mobile neurotechnology supports research in naturalistic settings. An evoked potential is a demanding test: it only appears if electrode contact, timing and signal-to-noise ratio are good enough to average many trials. A clean N100 in moving dogs is therefore stronger evidence than a raw EEG trace.

Animal EEG: Species Recorded So Far

The table separates peer-reviewed results from field demonstrations, so you can judge the level of evidence for your species.

Species Setup Level of evidence More information
Dog 8 gold cup electrodes, free movement, auditory oddball Peer-reviewed (IEEE SMC 2025) EEG in dogs
Horse Gold cup electrodes with adhesive paste in fur; dedicated horse caps Application guide EEG in horses
Pig Device on a halter, 4 gold cup electrodes, recorded while walking with real-time artifact removal Field demonstration (video) EEG of pigs
Cow Device on a halter in the barn, gold cup electrodes through fur Field demonstration (video) EEG of a cow
Goat Wireless recording during natural behavior Field demonstration EEG of a goat
Alpaca Gold cup electrodes through fur Field demonstration EEG of alpaca

Small laboratory animals such as rodents have not been recorded with this system so far.

Recommended Setup for Animal EEG Through Fur

Device

  • Unicorn BCI Core-8: 8 EEG channels, 24-bit resolution with oversampling, 250 Hz sampling rate, 23 g.
  • Wireless: Bluetooth 5 streaming and more than 6 hours of battery life, so the animal can move freely.
  • Mounting: The device attaches magnetically to a base station. On large animals, mount it on a halter or harness.

Electrodes

  • Gold cup electrodes are the first choice for fur. They are light, can be placed flexibly in the coat, and are held in position by sticky electrode paste. Their low weight helps to reduce artifacts.
  • g.SAHARA hybrid electrodes have eight pins long enough to penetrate layers of hair, and work dry or wet. They sit in a cap; g.tec offers caps for humans, horses and dogs in different sizes.
  • Choose the number of electrodes per study. The base stations accept the Core-8, so you can start with four electrodes, as in the pig recording, and scale up to eight.

Artifact handling

Movement is the main source of noise in animal EEG with free-moving animals. The OSCAR LIVE add-on removes movement artifacts in real time and runs in g.HIsys or in Python with g.Pype. It was used in the pig and cow recordings while the animals walked and fed.

How to Check Signal Quality in Animal EEG

  1. Inspect the raw trace while the animal is calm. Flat channels or large slow drifts point to poor electrode contact; add paste or reposition.
  2. Compute the power spectral density for each channel, as in the dog study. A clean spectrum shows a smooth 1/f decline without a dominant line-noise peak.
  3. Run a short evoked-potential test. An auditory oddball with tones takes a few minutes and tells you whether contact and timing are good enough for averaging.
  4. Annotate movement. Use video or observer notes to mark periods of chewing, head shaking or walking, and report how many epochs you kept.

How to Synchronize Animal EEG with Behavior

Behavioral neuroscience needs EEG and behavior on one time base. The Unicorn BCI Core-8 streams into Lab Streaming Layer (LSL) through g.Pype, and LSL is the standard way to put EEG, video, tracking and event markers on a shared clock.

  1. Stream the EEG to LSL with the LSL output node in g.Pype.
  2. Send behavior events as an LSL marker stream. A stimulus script, a button press by the observer, or an automatic detector can push markers such as “feeding start” or “tone 1”.
  3. Record everything with LabRecorder. It writes EEG, markers and any other LSL stream, such as eye tracking or a video timestamp stream, into one XDF file.
  4. Align offline tracking. Pose estimates from video (for example from DeepLabCut) can be aligned to the EEG using the frame timestamps recorded in the same session.

A minimal marker stream in Python:

from pylsl import StreamInfo, StreamOutlet

info = StreamInfo("Behavior", "Markers", 1, 0, "string", "behavior01")
outlet = StreamOutlet(info)
outlet.push_sample(["feeding_start"])  # call whenever the behavior occurs

And loading the synchronized recording afterwards:

import pyxdf

streams, header = pyxdf.load_xdf("session.xdf")
for s in streams:
    print(s["info"]["name"][0], len(s["time_stamps"]))

All access paths, file formats and licences for the Core-8 are listed in our guide to raw EEG data access. How the same tools connect to MNE-Python, EEGLAB, FieldTrip and OpenViBE is shown in our EEG interoperability matrix.

What Researchers Use Animal EEG For

  • Cognition and learning: how dogs, horses and farm animals process sounds, cues and training.
  • Welfare and stress: brain activity in response to handling, transport or housing conditions.
  • Sleep: gold cup electrodes are well suited to sleep recordings.
  • Anesthesia and surgery monitoring: research on brain activity during procedures and recovery.
  • Translational models: pigs and other large mammals as models for human neurological conditions.

Research Use

The Unicorn BCI Core-8 is a research device. It is not a veterinary medical device and is not intended for diagnosis or treatment of animals.

Collaborate on Validation

We are building a larger evidence base across species. If your lab or veterinary clinic records animal EEG and wants to compare setups, share data, or co-author a validation study, contact us. We are especially interested in species that have not been recorded yet.

START CONFIGURATOR

Animal EEG Through Fur: Frequently Asked Questions

Can EEG be recorded through animal fur?

Yes. Gold cup electrodes held in place with sticky electrode paste can be placed in the fur. With the Unicorn BCI Core-8, this setup recorded auditory evoked potentials with a clear N100 response in two awake, unrestrained dogs (IEEE SMC 2025).

Do animals need to be sedated or restrained?

No. The published dog recordings were made without sedation while the dogs moved freely. The 23 g wireless device can be mounted on a halter or harness.

Which species have been recorded with the Unicorn BCI Core-8?

Dogs (peer-reviewed), plus field recordings in a pig, a cow, a goat and an alpaca, and application work in horses.

How do I synchronize animal EEG with video or behavior?

Stream the EEG to Lab Streaming Layer with g.Pype, send behavior events as an LSL marker stream, and record all streams with LabRecorder into one XDF file. Video tracking can be aligned offline using frame timestamps.

How long can I record?

The Unicorn BCI Core-8 battery lasts more than 6 hours per charge.

How are movement artifacts handled?

The OSCAR LIVE add-on removes movement artifacts in real time in g.HIsys or in Python with g.Pype. It was used in the pig and cow recordings while the animals walked.

Is the Unicorn BCI Core-8 a veterinary medical device?

No. It is a research device and is not intended for diagnosis or treatment.

COMPANY
  • About
  • INSIGHTS
  • Events
  • Contact
  • Lost License
LEARN MORE
  • FIND G.TEC IN YOUR COUNTRY
  • PRODUCT CATALOG
  • MY ACCOUNT
  • NEWSLETTER
social media
Imprint | Terms & Conditions | Privacy Policy | Quality Management | Gender Equality Plan
© 2026 g.tec medical engineering GmbH Austria.
  • Sign in
  • New account

Do you have confirmation code? Click here

Forgot your password?

Do you have confirmation code? Click here

Back to login

Lost your password? Please enter your email address. You will receive mail with link to set new password.

Do you have confirmation code? Click here

Back to login