Highlights
very robust and easy to use |
|
unique adjustable bayonet sockets guarantee a slight pressure of the electrode on the skin (for best impedance values) |
|
ultra-flexible and light-weight electrode cables (100 cm) with safety connectors |
|
hermetic sealing of connection between electrode and cable |
|
gold (Au) electrodes (maintenance-free) or chloridable silver (Ag/AgCl) electrodes available |
The left panel shows the electrode positions of the fully equipped 65-electrodes cap. This configuration is suitable for most studies. If you need other positions or a subset ask for a customized solution. Best results are obtained when preparing the skin with an abrasive gel (see electrode montage). The systems are very capable. If you want to work with 2 or with 111 channels, we do have the best solution for your measurement.
|
EEG-Caps (65 electrode positions)
will be delivered with an elastic thoracic belt to fix the cap
![]() |
g.EEGcap, Size Small: 50 - 54 cm (Art.No.: 1003s) |
||
g.EEGcap, Size Medium: 54 - 58 cm (Art.No.: 1003m) |
|||
g.EEGcap, Size Large: 58 - 62 cm (Art.No.: 1003l) |
|||
Cap Set, 3 pcs-1 cap small, 1 cap middle, 1 cap large (Art.No.: 1110) |
EEG-Caps (111 electrode positions)
will be delivered with an elastic thoracic belt to fix the cap
![]() |
|
g.EEGcap, Size Large: 58 - 62 cm (Art.No.: 1013l) |
|
g.EEGcap, Size X-Large: 62 - 66 cm (Art.No.: 1013xl) |
Electro-Caps (16 electrode positions)
These charts show you the most important EEG-measurement for BCI and where the electrodes should be placed. Configuration A is for screening, configuration B is suitable for the measurement of sonsorimotoric rhythm and with the configuration C you can measure the P300 speller (avoked potential). The Electro-Caps are availabe in every presented configuration |
||
They are made of an elastic spandex-type fabric with recessed, pure tin electrodes attached to the fabric. The electrodes on the standard caps are positioned to the International 10-20 method of electrode placement. The standard-configuration is suitable for screening, P300 (avoked potential) and sensormotoric rhythm. |
![]() |
g.Electrocap, Size XSmall: 46 - 50 cm, green(Art.No.: ) |
||
g.Electrocap, Size Small: 50 - 54 cm, yellow (Art.No.: ) |
|||
g.Electrocap, Size Medium: 54 - 58 cm, red (Art.No.: ) |
|||
g.Electrocap, Size Large: 58 - 62 cm, blue (Art.No.: ) |
Electrodes
g.EEGelectrode Au (Art.No.: 1001) |
||
screwable gold-EEG-electrodes |
||
suitable for the EEG-cap, 1,5 mm safety connector, |
||
produced for long-term use and maintenance-free |
||
g.EEGelectrode Ag/AgCl (Art.No.: 1004) |
||
screwable Ag/AgCl-EEG-electrodes |
||
suitable for the EEG-cap, 1,5 mm safety connector, |
||
produced for long-term use and must be maintained (must be chlorinated) |
||
Active Electrodes
| g.GAMMAsys is a high-performance active electrode system for non-invasive electrophysiological derivations such as EEG, EMG, ECG, EOG and other signals. An additional pre-amplifier is located inside the electrode itself. The system is designed for use with biosignal amplifiers with monopolar (unipolar) inputs. It can be used with g.USBamp and with g.MOBIlab. Bipolar (differential) recordings are possible with recording systems capable of computing differential derivations from unipolar signals (e.g. g.USBamp). Electrodes are made of sintered Ag/AgCl and work in a frequency range of 0 - 100 kHz. The active electrodes can be used with all g.tec EEG caps as an alternative to the passive standard electrodes. The system avoids or reduces artifacts and signal noise resulting from high impedance between the electrode(s) and the skin (e.g. 50/60 Hz coupling, artifacts caused by electrode or cable movements, distorted signals or background noise). No modifications are required for the biosignal amplifier which can be used with or without the active electrode system. |
g.ACTIVEelectrode (Art.No.: 1015) |
||
screwable active sintered Ag/AgCl-EEG-electrodes |
||
suitable for the EEG-cap, special safety connector |
||
designed for long-term use and easy maintenance |
||
g.REFERENCEelectrode (Art.No.: 1017) |
||
active sintered reference electrode to apply at the earlobes |
||
special safety connector |
||
designed for long-term use and easy maintenance |
||
g.GROUNDelectrode (Art.No.: 1018) |
||
screwable active sintered Ag/AgCl-ground-electrode |
||
suitable for the EEG-cap, special safety connector |
||
designed for long-term use and easy maintenance |
||
g.GAMMAbox (Art.No.: 1016) |
||
| Driver/interface box with battery supply for active electrodes | ||
g.MOBIlab+GAMMAconnector (Art.No.: 1019b) |
||
| Connection cable between the g.MOBIlab+ and the g.GAMMAbox | ||
g.USBampGAMMAConnector (Art.No.: 1019a) |
||
| Connection cable between the g.USBamp and the g.GAMMAbox | ||
g.BSampGAMMAconnector (Art.No.: 1019c) |
||
| Connection cable between the g.BSamp and the g.GAMMAbox | ||
g.CUSTOMIZEDGAMMAconnector (Art.No.: 1019d) |
||
| Connection cable between a third party amplifier and the g.GAMMAbox | ||
Cables
![]() |
g.USBamp adapter Cable for ElectroCap (Art.No.: 0219a) |
|
adapter cable for 25 pin SUB-D 16 channels Electrocap for g.USBamp |
||
g.BSamp adapter Cable for ElectroCap (Art.No.: 0219c) |
||
adapter cable for 25 pin SUB-D 16 channels Electrocap for g.BSamp |
||
Gels and Pastes
Abrasive electrode-gel (Art.No.: 1031) |
||
is recommended to prepare the skin before the measurement of EKG, EEG, EMG |
||
high conductivity, microbiologically clean, water soluble |
||
Elefix (Art.No. 1030) |
||
EEG Electrode paste, low impedance highly conductive gel, specially formulated to stick the electrodes on the skin without additional adhesive disks |
||
high conductivity, microbiologically clean, water soluble |
||