Highlights
very robust and easy to use |
|
unique adjustable bayonet sockets guarantee a slight pressure of the electrode on the skin (for best impedance values) |
|
ultra-flexible and light-weight electrode cables (100 cm) with safety connectors |
|
hermetic sealing of connection between electrode and cable |
|
gold (Au) electrodes (maintenance-free) or chloridable silver (Ag/AgCl) electrodes available |
The left panel shows the electrode positions of the fully equipped 65-electrodes cap. This configuration is suitable for most studies. If you need other positions or a subset ask for a customized solution. Best results are obtained when preparing the skin with an abrasive gel (see electrode montage). The systems are very capable. If you want to work with 2 or with 111 channels, we do have the best solution for your measurement.
|
EEG-Caps (65 electrode positions)
will be delivered with an elastic thoracic belt to fix the cap
![]() |
g.EEGcap, Size Small: 50 - 54 cm (Art.No.: 1003s) |
||
g.EEGcap, Size Medium: 54 - 58 cm (Art.No.: 1003m) |
|||
g.EEGcap, Size Large: 58 - 62 cm (Art.No.: 1003l) |
|||
Cap Set, 3 pcs-1 cap small, 1 cap middle, 1 cap large (Art.No.: 1110) |
EEG-Caps (111 electrode positions)
will be delivered with an elastic thoracic belt to fix the cap
![]() |
|
g.EEGcap, Size Large: 58 - 62 cm (Art.No.: 1013l) |
|
g.EEGcap, Size X-Large: 62 - 66 cm (Art.No.: 1013xl) |
Passive Electrodes
g.EEGelectrode Au (Art.No.: 1001) |
||
screwable gold-EEG-electrodes |
||
suitable for the EEG-cap, 1,5 mm safety connector, |
||
produced for long-term use and maintenance-free |
||
g.EEGelectrode Ag/AgCl (Art.No.: 1004) |
||
screwable Ag/AgCl-EEG-electrodes |
||
suitable for the EEG-cap, 1,5 mm safety connector, |
||
produced for long-term use and must be maintained (must be chlorinated) |
||
Abrasive electrode-gel (Art.No.: 1031) |
||
is recommended to prepare the skin before the measurement of EKG, EEG, EMG |
||
high conductivity, microbiologically clean, water soluble |
||
Elefix (Art.No. 1030) |
||
EEG Electrode paste, low impedance highly conductive gel, specially formulated to stick the electrodes on the skin without additional adhesive disks |
||
high conductivity, microbiologically clean, water soluble |
||
Active Electrodes:
An additional pre-amplifier is located inside the electrode itself. The system is designed for use with biosignal amplifiers with monopolar (unipolar) inputs. It can be used with g.BSamp, g.USBamp and with g.MOBIlab+. Bipolar (differential) recordings are possible with recording systems capable of computing differential derivations from unipolar signals (e.g. g.USBamp). Electrodes are made of sintered Ag/AgCl and work in a frequency range of 0 - 100 kHz. The active electrodes can be used with the g.EEGcap as an alternative to the passive standard electrodes. |
g.ACTIVEelectrode (Art.No.: 1015) : |
|
g.ACTIVEground (Art.No.: 1018) : |
g.GAMMAgel: |
g.GAMMAbox (Art.No.: 1016) |
|
| g.USBampGAMMAconnector (Art.No.: 1019a) Connection cable between the g.USBamp and the g.GAMMAbox |
|
| g.MOBIlab+GAMMAconnector (Art.No.: 1019b) Connection cable between the g.MOBIlab+ and the g.GAMMAbox |
|
| g.BSampGAMMAconnector (Art.No.: 1019c) Connection cable between the g.BSamp and the g.GAMMAbox |
|
| g.CUSTOMIZEDGAMMAconnector (Art.No.: 1019d) Connection cable between a third party amplifier and the g.GAMMAbox |