Electrodes and Cables
g.GAMMAsys and g.EEGcap are high-performance active and passive electrode systems for non-invasive electrophysiological derivations such as EEG, EMG, ECG, EOG and other signals. Active electrodes have an additional ultra-low noise pre-amplifier located inside the electrode. The system is designed for use with biosignal amplifiers, like g.BSamp, g.USBamp and with g.MOBIlab+. Electrodes are made of sintered Ag/AgCl and work in a frequency range of 0 - 100 kHz. The active electrodes can be used with all g.tec EEG caps as an alternative to the passive standard electrodes. The system avoids or reduces artifacts and signal noise resulting from high impedance between the electrode(s) and the skin (e.g. 50/60 Hz coupling, artifacts caused by electrode or cable movements, distorted signals or background noise). No modifications are required for the biosignal amplifier which can be used with or without the active electrode system. |
Electrodes for use with g.GAMMACap |
|
g.GAMMAcap uses active or passive ladybird or butterfly electrodes that are inserted into the specific electrode position. The gel is inserted through the hole in the middle of the electrode. The ring electrode g.LADYbird normally stays inside the cap and is also cleaned together with the cap. A big advantage is therefore the montage speed. The g.BUTTERFLY electrode can be removed after each measurement. The caps has also electrode labels to easily identify positions. |
|
g.LADYbird is inserted
into the cuts in the g.GAMMAcap. The electrodes can be
removed to configure
a new montage by
yourself. |
g.BUTTERFLY electrodes
are faster to insert and
to remove. The special
shape allow to use the
electrode for many
different materials. |
g.LADYbird (Art.No.: 1033): |
|
g.LADYbirdGND (Art.No.: 1034): |
|
g.LADYbirdPASSIVE (Art.No.: 1035): |
|
g.BUTTERFLY (Art.No.: 1036): |
g.BUTTERFLYgnd (Art.No.: 1037): |
Electrodes for use with g.EEGcap g.EEGcap uses screwable active or passive electrodes which are inserted into the specific electrode position and are locked with a 90° turn. The gel is applied to the skin before the electrode is inserted. After the measurement the electrodes are removed. A big advantage is that the insertion deepness can be adjusted. |
|
g.EEGelectrode Au (Art.No.: 1001): |
|||
g.EEGelectrode Ag/AgCl (Art.No.: 1004): |
g.ACTIVEelectrode (Art. No.: 1015): |
|
g.ACTIVEground (Art.No.: 1018): |
Other Electrodes
g.GAMMAearclip Au (Art.No.: 1038): |
|
g.GAMMAearclip Ag/AgCl (Art.No.: 1039): |
|
|
g.GAMMAclip (Art.No.: 1024): |
g.GAMMAclipREF (Art.No.: 1024): |
|
g.GAMMAclipGND (Art.No.: 1025): |
|
| EEG-electrode Au (Art.No.: 1002): 10 pieces; disk electrodes; electrode length 150 cm; 10 mm diameter |
|
Ear-clip electrode Au (Art.No.: 1101): gold; to apply at the earlobes; 2 pieces (one for each ear) |
|
EOG sintered electrode, 14 mm (Art.No.: 1044): |
|
![]() |
ECG electrode cable with clip lead (Art.No.: 1009): 3 leads/piece; 150 cm length; for disposable electrodes |
finger electrodes for g.GSRsensor (Art.No.: 20312): |
|
disposable Ag/AgCl electrodes (Art.No.: 1032): |
|
![]() |
double-sided adhesive washers (Art.No.: 1042): 500 pieces; for 14 mm reusable EOG Ag/AgCl electrodes |
g.GAMMAbox & connectors to the amplifiers
g.GAMMAbox for 16 channels (Art.No.: 1016a): |
|
g.GAMMAbox for 8 channels (Art.No.: 1016b): |
|
g.USBampGAMMAconnector (Art.No.: 1019a): connector cable between the g.USBamp and the g.GAMMAbox |
|
g.MOBIlab+GAMMAconnector (Art.No.: 1019b): connector cable between the g.MOBIlab+ and the g.GAMMAbox |
|
g.BSampGAMMAconnector (Art.No.: 1019c): connector cable between the g.BSamp and the g.GAMMAbox |
|
g.CustomizedGAMMAconnector (Art.No.: 1019d): connector cable between a third party amplifier and the g.GAMMAbox |
|
g.EXTENTIONbox für g.GAMMAbox (Art.No.: 1022): for additional 16 active electrodes; without ground and reference |
Cables
shortcut jumper cable for 2 channels (Art.No.: 0223): shortcut cable for 2 channels, medical safety connector; can be daisy chained |
|
![]() |
shortcut cable (Art.No.: 0224, 0215, 0218): for 3, 7 or 15 medical safety sockets of 1,5 mm, highly flexible cables |
Gels and Pastes
abrasive gel (Art.No.: 1031): |
||
"Elefix" (Art.No.: 1030): |
g.GAMMAgel (Art.No. 1021): |